http://www.youtube.com/embed/sP6nd-aAnbQ
http://www.youtube.com/embed/44wIg8awEU0
Facility may involved for Q&C:
Material:
lChemical composition:
Ø OBLF Spectrometer with 29 channels in bi-metal of AL+FE
lMechanical Property
Ø Hardness test
Ø Mechanical property inspection
Ø Impact inspection
lMicrostructure:
Ø Microscope Metallographic Analysis as per AQL based on heating number
lStructure tightness
Ø Destructive test
Ø Weight test
Crack inspection:
lMT
lUT
lX-ray
Coating test:
lCoating thickness tester
lSalt spray test
Dimension:
lUniversal Measuring
lGo & No-go gauge
lCMM
Leakage check
Press load test
Ø Will be effected acc. to different projects.
Output of our Q.C.:
lFinished products:
Ø meets AQL requirement. 50ppm, 500ppm, 1000ppm, 5000ppm may vary acc. to project.
lQ.C report:
Ø Dimensional report(all dimension/key dimension)
Ø Material report in 3.1 acc. to EN10204(2004)
Ø Other detailed report like heat treatment curve, crake testing,
Ø pressure testing, leakage inspection also available if needed.
lImprovement plan